144 research outputs found

    The imaging properties of the Gas Pixel Detector as a focal plane polarimeter

    Full text link
    X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a telescope, will increase the sensitivity of orders of magnitude. Moreover, since it can measure the energy, the position, the arrival time and the polarization angle of every single photon, allows to perform polarimetry of subsets of data singled out from the spectrum, the light curve or the image of source. The GPD has an intrinsic very fine imaging capability and in this work we report on the calibration campaign carried out in 2012 at the PANTER X-ray test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of Garching (Germany) in which, for the first time, we coupled it to a JET-X optics module with a focal length of 3.5 m and an angular resolution of 18 arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small mission. We derived the imaging and polarimetric performance for extended sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the XIPE configuration, discussing also possible improvements by coupling the detector with advanced optics, having finer angular resolution and larger effective area, to study with more details extended objects.Comment: Accepted for publication in The Astrophysical Journal Supplemen

    Treatment of wounds colonized by multidrug resistant organisms in immune-compromised patients: a retrospective case series.

    Get PDF
    Immune-compromised patients incur a high risk of surgical wound dehiscence and colonization by multidrug resistant organisms. Common treatment has been debridement and spontaneous secondary healing.All immune-compromised patients referred to our Institution between March 1, 2010 and November 30, 2011 for dehiscent abdominal wounds growing multidrug resistant organisms were treated by serial wound debridements and negative pressure dressing. They were primarily closed, despite positive microbiological cultures, when clinical appearance was satisfactory.Nine patients were treated by direct wound closure, five had been treated previously by secondary intention healing.According to our results, fast healing can be safely obtained by closure of a clinically healthy wound, despite growth of multidrug resistant organisms, even in immune-compromised patients

    Contact-force monitoring increases accuracy of right ventricular voltage mapping avoiding “false scar” detection in patients with no evidence of structural heart disease

    Get PDF
    Purpose: Electroanatomical mapping (EAM) could increase cardiac magnetic resonance imaging (CMR) sensitivity in detecting ventricular scar. Possible bias may be scar over-estimation due to inadequate tissue contact. Aim of the study is to evaluate contact-force monitoring influence during EAM, in patients with idiopathic right ventricular arrhythmias. Methods: 20 pts (13 M; 43 ± 12 y) with idiopathic right ventricular outflow tract (RVOT) arrhythmias and no structural abnormalities were submitted to Smarttouch catheter Carto3 EAM. Native maps included points collected without considering contact-force. EAM scar was defined as area ≥1 cm2 including at least 3 adjacent points with signal amplitude (bipolar <0.5 mV, unipolar 3,5 mV), surrounded by low-voltage border zone. EAM were re-evaluated offline, removing points collected with contact force <5 g. Finally, contact force-corrected maps were compared to the native ones. Results: An EAM was created for each patient (345 ± 85 points). After removing poor contact points, a mean of 149 ± 60 points was collected. The percentage of false scar, collected during contact force blinded mapping compared to total volume, was 6.0 ± 5.2% for bipolar scar and 7.1 ± 5.9% for unipolar scar, respectively. No EAM scar was present after poor contact points removal. Right ventricular areas analysis revealed a greater number of points with contact force < 5 g acquired in free wall, where reduced mean bipolar and unipolar voltage were recorded. Conclusions: To date this is the first work conducted on structurally normal hearts in which contact-force significantly increases EAM accuracy, avoiding “false scar” related to non-adequate contact between catheter and tissue

    Measurement of the atmospheric muon flux with the NEMO Phase-1 detector

    Get PDF
    The NEMO Collaboration installed and operated an underwater detector including prototypes of the critical elements of a possible underwater km3 neutrino telescope: a four-floor tower (called Mini-Tower) and a Junction Box. The detector was developed to test some of the main systems of the km3 detector, including the data transmission, the power distribution, the timing calibration and the acoustic positioning systems as well as to verify the capabilities of a single tridimensional detection structure to reconstruct muon tracks. We present results of the analysis of the data collected with the NEMO Mini-Tower. The position of photomultiplier tubes (PMTs) is determined through the acoustic position system. Signals detected with PMTs are used to reconstruct the tracks of atmospheric muons. The angular distribution of atmospheric muons was measured and results compared with Monte Carlo simulations.Comment: Astrop. Phys., accepte

    Development and Multicenter Validation of a Novel Immune-Inflammation-Based Nomogram to Predict Survival in Western Resectable Gastric and Gastroesophageal Junction Adenocarcinoma (GEA): The NOMOGAST

    Get PDF
    Background. More than 50% of operable GEA relapse after curative-intent resection. We aimed at externally validating a nomogram to enable a more accurate estimate of individualized risk in resected GEA. Methods. Medical records of a training cohort (TC) and a validation cohort (VC) of patients undergoing radical surgery for c/uT2-T4 and/or node-positive GEA were retrieved, and potentially interesting variables were collected. Cox proportional hazards in univariate and multivariate regressions were used to assess the effects of the prognostic factors on OS. A graphical nomogram was constructed using R software’s package Regression Modeling Strategies (ver. 5.0-1). The performance of the prognostic model was evaluated and validated. Results. The TC and VC consisted of 185 and 151 patients. ECOG:PS > 0 (p < 0.001), angioinvasion (p < 0.001), log (Neutrophil/Lymphocyte ratio) (p < 0.001), and nodal status (p = 0.016) were independent prognostic values in the TC. They were used for the construction of a nomogram estimating 3- and 5-year OS. The discriminatory ability of the model was evaluated with the c-Harrell index. A 3-tier scoring system was developed through a linear predictor grouped by 25 and 75 percentiles, strengthening the model’s good discrimination (p < 0.001). A calibration plot demonstrated a concordance between the predicted and actual survival in the TC and VC. A decision curve analysis was plotted that depicted the nomogram’s clinical utility. Conclusions. We externally validated a prognostic nomogram to predict OS in a joint independent cohort of resectable GEA; the NOMOGAST could represent a valuable tool in assisting decision-making. This tool incorporates readily available and inexpensive patient and disease characteristics as well as immune-inflammatory determinants. It is accurate, generalizable, and clinically effectivex

    XIPE: the x-ray imaging polarimetry explorer

    Get PDF
    XIPE, the X-ray Imaging Polarimetry Explorer, is a mission dedicated to X-ray Astronomy. At the time of writing XIPE is in a competitive phase A as fourth medium size mission of ESA (M4). It promises to reopen the polarimetry window in high energy Astrophysics after more than 4 decades thanks to a detector that efficiently exploits the photoelectric effect and to X-ray optics with large effective area. XIPE uniqueness is time-spectrally-spatially- resolved X-ray polarimetry as a breakthrough in high energy astrophysics and fundamental physics. Indeed the payload consists of three Gas Pixel Detectors at the focus of three X-ray optics with a total effective area larger than one XMM mirror but with a low weight. The payload is compatible with the fairing of the Vega launcher. XIPE is designed as an observatory for X-ray astronomers with 75 % of the time dedicated to a Guest Observer competitive program and it is organized as a consortium across Europe with main contributions from Italy, Germany, Spain, United Kingdom, Poland, Sweden
    • …
    corecore